Thermocouple Temperature Transducers

Supplied by
  1. Howard Butler Ltd

    Thermocouple Temperature Transducers
    The M100-TJ1 and TK1 measure the millivolt drop of J and K type thermocouples respectively. Thermocouples are made from two dissimilar metals and as the temperature rises, the mV accross the thermocouple increases. The millivolts voltage developed corresponds to the change in temperature, thermocouple manufacturers provide tables showing temperature versus voltage drop. The M100 TJ1/TK1 measures this voltage change and converts it to an output signal that corresponds to the temperature being monitored. The output from the M100-TJ1/TK1 is not linearised. Thermocouple temperature measurement is used in a variety of applications, including monitoring of temperature of furnaces etc. The M100 thermocouple transducer is provided with automatic cold junction temperature compensation over the range 0-50ºC. Also provided is thermocouple break protection should the thermocouple leads break, the output from the transducer will go to its maximum or minimum output value, depending on which option is chosen at the time of ordering.