Smoke Ventilation

In fire situations, most deaths and injuries are caused by fumes and smoke, not flames. Having an efficient and effective means of ventilating smoke and noxious fumes saves lives and can assist the emergency services greatly in facilitating fire fighting and evacuation.

Bilco smoke vents are designed to satisfy Building Regulations and meet Approved Document B, BS 9999 (which supercedes BS5588) and European Standards enshrined in EN 12101. As of 1st July 2013, the Construction Products Regulation came into force which requires smoke vents to be CE marked and to be supplied with a Declaration of Conformity. Bilco smoke vents have been fully tested and carry the CE mark as required by the new legislation.

For the EN 12101 key areas of the regulations are that the covers must reach the fire open position within 60 seconds and that single covers open to 140° to ensure there are no negative wind coefficients ie wind blowing smoke back into the building.

Bilco smoke vents are also compatible with other guidance and codes of practices, for example those issued by the British Research Establishment such as BRE 79204.

Showing 15 of 52 Products
  1. Fall Protection Grating

    Fall Protection Grating
    Fall Protection Grating System allows workers to safely inspect pumps and monitor underground areas. Meeting OSHA 29 CFR 1910.23 requirements for fall protection on access doors the system is now available from Bilco as a factory installed option on selected models.
  2. Fall Protection Grating

    Fall Protection Grating
    Fall Protection Grating System allows workers to safely inspect pumps and monitor underground areas. Meeting OSHA 29 CFR 1910.23 requirements for fall protection on access doors the system is now available from Bilco as a factory installed option on selected models.
  3. Keyed Lock Kit - Classic Steel

    Keyed Lock Kit - Classic Steel
    Buy on-line! Enjoy the convenience of locking and unlocking your Classic Series Bilco basement door from the outside. Install a Bilco keyed entry lock and save the trip into the basement to lock or unlock the door.
  4. Option - Grating Covers

    Option - Grating Covers
    Bilco floor vault and sidewalk doors may be specified to include steel (shown) or aluminum grating. Grating panels are available for pedestrian and wheel load applications.
  5. Option - Motor Operation

    Option - Motor Operation
    Bilco Floor Doors can be supplied with electric motor operation to open and close covers with the push of a button. Motor operation provides a convenient means of ventilating work areas in manufacturing facilities. Product is supplied with built-in motor operator push button control station and wiring diagram.
  6. Option - Special Finishes

    Option - Special Finishes
    New! Bilco products are now available with a factory applied powder coat paint finish. Click details for more information on this finish and for a list of other custom finish options available.
  7. Type FR - Fire Rated Floor Door

    Type FR - Fire Rated Floor Door
    Maintains the fire rating of a 2-hour floor ceiling assembly where access is required between building floors. Fire rated floor doors feature an automatic closing system intumescent fire resistant coating and a pan cover designed to accept architectural flooring materials for concealed access. Type FR doors are available in a number of UL-Listed standard sizes.
  8. Type HLC - High Load Capacity

    Type HLC - High Load Capacity
    The Type HLC is specially designed for extreme loading conditions generated by vehicles such as large aircraft heavy equipment and forklift trucks. Doors are constructed of steel and covers are reinforced for a 200 psi + 30% impact live load.
  9. Type J-AL - Channel Frame - 300 PSF

    Type J-AL - Channel Frame - 300 PSF
    Constructed with a channel frame for use in exterior applications or in those situations where there is concern of water or other liquids entering the access opening. Type J-AL floor access doors feature aluminum construction type 316 stainless steel hardware and engineered lift assistance for easy one-hand operation. Available in a number of standard single leaf and double leaf (Type JD-AL) sizes and special sizes can be specified to meet unique access requirements.
  10. Type J-AL - Channel Frame - H-20 Loading

    Type J-AL - Channel Frame - H-20 Loading
    Constructed with a channel frame for use in exterior applications or in those situations where there is concern of water or other liquids entering the access opening. Type J-AL H20 floor access doors are reinforced for AASHTO H-20 wheel loading and feature aluminum construction type 316 stainless steel hardware and engineered lift assistance for easy one-hand operation. Available in a number of standard single leaf and double leaf (Type JD-AL H20) sizes and special sizes can be specified.