E-T-A Circuit Breakers Ltd
We provide comprehensive and globally renowned solutions for your electronic systems. For the design and production of circuit breakers for equipment protection, we provide superior services, unmatched throughout the field.
We also offer the widest range of products for circuit protection in every industrial application. Our unrivalled supply of circuit protection devices includes:
- Thermal overcurrent circuit breakers
- Thermal-magnetic overcurrent circuit breakers
- Hydraulic-magnetic and magnetic overcurrent circuit breakers
- High performance circuit breakers and battery switches
Filter products and services
- View all categories
- Battery Isolation Switches
- Circuit Breakers
- DC Disconnects
- DC Servo Motors
- Electronic Overcurrent Protection Devices
- Office Application Software
- Power Controllers
- Power Distribution Systems
- Power Management Systems
- Power Outlets & Sockets
- Power Relays
- Power Supplies
- Rocker Switches
-
Electronic Overcurrent Protector REF16-S102-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
Without signal input
Signal output F - signal contact, break contact (only REF16-S102)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)
Request a Quote Supplied by E-T-A Circuit Breakers Ltd -
Electronic Overcurrent Protector REF16-S104-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
Without signal input
Status output SF (only REF16-S114, REF16-124)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)
Request a Quote Supplied by E-T-A Circuit Breakers Ltd -
Electronic Overcurrent Protector REF16-S107-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
Without signal input
Status output SF inverted (only REF16-S117, REF16-S127)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)
Request a Quote Supplied by E-T-A Circuit Breakers Ltd -
Electronic Overcurrent Protector REF16-S110-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
With control input IN+ (only REF16-S114, REF16-S117)
Without without signal output (only REF16-S100)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)
Request a Quote Supplied by E-T-A Circuit Breakers Ltd -
Electronic Overcurrent Protector REF16-S111-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
With control input IN+ (only REF16-S114, REF16-S117)
Signal output F - signal contact, make contact (only REF16-S101)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)
Request a Quote Supplied by E-T-A Circuit Breakers Ltd -
Electronic Overcurrent Protector REF16-S112-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
With control input IN+ (only REF16-S114, REF16-S117)
Signal output F - signal contact, break contact (only REF16-S102)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)
Request a Quote Supplied by E-T-A Circuit Breakers Ltd -
Electronic Overcurrent Protector REF16-S114-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
With control input IN+ (only REF16-S114, REF16-S117)
Status output SF (only REF16-S114, REF16-124)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)
Request a Quote Supplied by E-T-A Circuit Breakers Ltd -
Electronic Overcurrent Protector REF16-S117-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
With control input IN+ (only REF16-S114, REF16-S117)
Status output SF inverted (only REF16-S117, REF16-S127)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)
Request a Quote Supplied by E-T-A Circuit Breakers Ltd -
Electronic Overcurrent Protector REF16-S120-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
With reset input RE (only REF16-S124, REF16-S127)
Without without signal output (only REF16-S100)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)
Request a Quote Supplied by E-T-A Circuit Breakers Ltd -
Electronic Overcurrent Protector REF16-S121-DC 24 V-1A
It provides selective protection for all DC 24 V load circuits at a width of only 12.5 mm. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection at typically 1.25 times rated current. Plugged into an E-T-A socket, which is available with screw terminals or screwless terminals, the REF16-S provides ease of installation. The sockets allow power distribution and signalling via plug-in type jumpers. In addition the REF16-S latches on when plugged into the socket and by means of coding pins a clear assignment to current ratings or slots is possible. Dimensions are in compliance with the standard DIN 43880 for the installation of built-in units.
Electronic circuit breaker with current limit
Mounting and design: plug-in type
Version without physical isolation
With reset input RE (only REF16-S124, REF16-S127)
Signal output F - signal contact, make contact (only REF16-S101)
Rated voltage DC 24 V
Current ratings:- 0.5A
- 1A
- 2A
- 3A
- 4A
- 6A
- 8A (without REF16-S102)
- 10A (without REF16-S102)